SERVICES AND LABS
LV CALIBRATION
Our motivation is excellence in metrology. For this reason, the
LCOE has been for more than 70 years a national benchmark in the
calibration of low voltage measurement instruments. Two key
factors support our work, the high qualification of our technicians
and the most accurate measurement systems.
LCOE's calibration services scope from high-precision standards to
industrial measurement systems. We conduct a periodic review of
our calibration procedures to guarantee our customers the lowest
calibration uncertainty. To consult our CMCs accredited by ENAC,
see the following link: Nº1/LC10.001
ELECTRICITY DC & LOW FREQUENCY
Knowledge, research and expertise are essential to developing metrology on constantly evolving areas such as electricity.
Accurate energy
easurement is essential for utilities, businesses and consumers. The safety of the facilities is based on accurate and precise measurements, that is why the main transformer manufacturers, facilities inspection companies and industrial laboratories trust LCOE for the calibration of their measurement systems such as:
Passive standards (resistances, capacitors and inductances), high-resolution multimeters and calibrators, current and voltage transformers, transformer ratiometers, RLC bridges and the most of electrical measurement equipment in a wide measurement range.
INSTRUMENT | RANGE |
---|---|
Instrument | Ranges |
Multimeters | Up to 8½ digits |
Calibrators | Any high performance |
VTs | Up to 1kV |
CTs | Up to 10 kA |
Ratio bridges | CTs ratio up to 10 A VT ratio up to 400 V |
Power analyzers | Up to 400 kW |
Standards | |
Resistances | 1 μΩ ≤ R ≤ 100 TΩ |
Capacitances | 1 pF ≤ C ≤ 1 F |
Inductances | 100 μH ≤ L ≤ 10 H |
RLC bridges | 0,1 Ω ≤ R ≤ 1 MΩ 100 μH ≤ L ≤ 10 H 1 pF ≤ C ≤ 1 F |
TIME & FREQUENCY
Accurate time measurement is a must for highfrequency applications in electronics, switch response time, angular velocity measurement of precision motors, and other essential areas in the industry.
The LCOE's metrological capacities are at the service of these applications in the calibration of oscilloscopes, frequency meters, optical tachometers, differential trip testers, switchgear testers , signal generators and all kinds of time and frequency measurement devices.
MAGNITUDE | RANGE |
---|---|
Frequency | 10 mHz ≤ f ≤ 100 MHz |
Period | 2 ns ≤ T ≤ 5 s |
Time interval | 40 ms ≤ Δt ≤ 100 s |
Bandwidth | Up to 1 GHz |
OPTICS
The precision in the measurement of light is very relevant in both exterior and interior lighting.
Photometry applied to the lighting of public roads, tunnels, accesses, etc. It has implications for road safety. In Spain, the REEAE regulation and RD 1890/2008 regulate light limits outdoors.
In interior lighting, photometry is applied to the health of workplaces, both in offices and in industry, where light limits are required with consequences on occupational health and safety (EN 12464).
The LCOE optics laboratory offers calibration services for lux meters from 0.4 lux to 5000 lux and luminance meters from 1.8 cd / m2 to 1000 cd / m2.
INSTRUMENT | RANGE |
---|---|
Lux meters 1 | 0.4 lux ≤ Ev ≤ 5000 lux |
Luminance meters | 1.8 cd/m2 ≤ Lv ≤ 1000 cd/m2 |
Lux meters 2 | 20 lux ≤ Ev ≤ 200 lux |
1CIE standard illuminant A 2LED lamps and fluorescence |
MAGNETISM
The measurement of magnetic induction is important in industrial applications, such as the manufacture of transformers, surface treatments in metallurgy and in the safety of installations such as substations. The LCOE offers calibration services for Hall effect gaussmeters with flat or axial probes and permanent magnets.
INSTRUMENT | RANGE |
---|---|
Hall effect gaussmeters with flat or axial probes | 0,0001 T ≤ B ≤ 1 T |
Permanent magnets |
METROLOGY CONSULTING & TRAINING
Do not hesitate to contact us to advise you on any aspect related to metrology: Calibration of measurement systems, calculation of
measurement uncertainties, etc. You can direct your inquiries to: seccion6@ffii.es
In addition, the LCOE parent company offers courses on laboratory requirements under the ISO / IEC 17025 standard. See the training
offer at the following link: https://ffii.es/formacion/